DE90B20041P000000000, bộ truyền áp suất Fischer Mess
DE90B20041P000000000 là bộ truyền áp suất chênh lệch kỹ thuật số (Digital Differential Pressure Transmitter) thuộc dòng FISCHER PRO-LINE® DE90 của hãng FISCHER Mess- und Regeltechnik GmbH – Đức

Một số dòng thường gặp
- DA series – đồng hồ đo chênh áp.
- DS series – công tắc chênh áp.
- DE series – transmitter chênh áp.
- ME series – thiết bị đo/điều khiển áp suất.
- KFM series – thiết bị đo chênh áp/lưu lượng.
Các Dòng Fischer Mess
|
Code: DE49B20040BH00MW
Description: ExDigital Differential pressure Transmitter
Measuring range -25…+25 mbar
Version standard
Measuring unit standard (increasing curve)
Pressure connection threaded hose coupling for 6/4 mm hose
Elecrical output signal 4-20mA (2-wire)
Power supply 12-30 V DC
Electrical connection M12 round shell multi pin connector
Mounting wall mounting plate
|
Code: DE85B52M41B90CEW0000
Description: Differential Pressure Transmitter ECO-LINE
Measuring range -160 …+160 mbar
Characteristic curve deviation 1,0%
Process connection Alu screw connection for 8mm hose
Output signal – Power supply 4…20mA, 24V DC, 2-wire
Measured value display 4-digit
Electrical connection cable gland
Assembly option wall mounting
|
|
Code: DE1601VA20B90H00
Description: Differential Pressure Transmitter
Measuring range 0 …0,6 bar
Measuring diaphragm/ gaskets Viton
Pressure chamber Aluminium
Pressure connection 6mm cutting ring/ steel
Output signal 4-20mA 2-wire
Power supply 24 VDC +-10%
Electrical connection plug acc. DIN EN 175301-803-A
|
Code: DS1102VDYYBKYY00D0544
Description: Differential Pressure Switch
Measuring range 0 …1 bar
Measuring diaphragm/ gaskets Viton
Pressure chamber Aluminium/ HART-COAT
With 2 adjustable microswitches
Electrical connection cable terminal box
|
|
Code: DE49B20040BH00MW
Description: ExDigital Differential pressure Transmitter
Measuring range -25…+25 mbar
Version standard
Measuring unit standard (increasing curve)
Pressure connection threaded hose coupling for 6/4 mm hose
Elecrical output signal 4-20mA (2-wire)
Power supply 12-30 V DC
Electrical connection M12 round shell multi pin connector
Mounting wall mounting plate
|
Code: DE2802M290PL000P
Description: Differential pressure transmitter
Measuring range 0…1bar
Pressure chamber brass; diapraghm NBR
Pressure connection 8 mm cutting ring/ brass
Electrical connection M16x1,5 cabel connection
Output signal 4-20 mA, 3-wire
Power supply 24V AC/DC (20-30V)
Approval variants standard version
Protection IP65
|
|
Code: DE1601VA20B90H00
Description: Differential Pressure Transmitter
Measuring range 0 …0,6 bar
Measuring diaphragm/ gaskets Viton
Pressure chamber Aluminium
Pressure connection 6mm cutting ring/ steel
Output signal 4-20mA 2-wire
Power supply 24 VDC +-10%
Electrical connection plug acc. DIN EN 175301-803-A
|
Code: DE90R50040P000000000
Description: Digital Differential pressure transmitter PRO-LINE
Measuring range channel 1 -160…+160 mbar
Measuring range channel 2 without
Process connection aluminium screw connection for 6mm hose
Output signal (preset) 4-20 mA, 3-wire
Special function none
Special features none
Approval not selected
lid color anthracite/ green
Membrane keypad Fischer
Configuration standard
|
|
Model: DE90B20041P000000000
Description:
Digital Differential Pressure Transmitter PRO-LINE
Measuring range channel 1 -25..+25 mbar
Measuring range channel 2 without
Process connection aluminium screw connection for 8 mm hose
Output signal (preset) 4…20 mA, 3-wire
Special function none
Special features: none
Approval not selected
lid color anthracite/green
Membrane keypad Fischer
Configuration standard
|
Code: DE2802M290PL0000
Description: Differential pressure Transmitter
Measuring range 0…1 bar
pressure chamber brass; diapraghm NBR
Pressure connection 8mm cutting ring/ brass
Electrical connection M16X1.5 cabel connection
Output signal 4 -20 Ma, 3 Wire
Power supply 24 V AC/ DC (20-30V)
Approval variants standard version
Protection IP54
|
|
Model: NK103000000100S0
Description:
Level Limiter
Flange DIN EN 1092-1 From B1 DN65 PN16; 1.0425 10bar (350’C)
with 1 micro switch
vesion SIL 1/2 (SIL3 redundant)
Medium thermal oil
Protection class IP55
Capacity 6 ampere
with control key
TUV approval acc. to DIN 4754
Registration No:
DIN 1D016/07
|
Code: DS3105FN00A1
Description: Differential pressure Switch
Measuring range/ switching range 0…4 bar/ 0,40…4,0 bar
Nominal pressure 16 bar
Version (measuring system) brass/ viton
Pressure connection female thread G1/8″
with 1 adjustable mikroswitch; closer
Electrical connection 1 m numbered cable, prewired
|
|
Model: DS1102VDYYBKYY00D0544
Differential pressure switch
Measuring range 0…1 bar
Measuring diaphragm/ gaskets Viton
Pressure chamber Aluminum/HART-COAT®
With 2 adjustable micro switches
Electrical connection Cable terminal box
***
– Design as top flow monitoring top
– Protection class IP65
– Power supply 230V, 50Hz
– Max operating pressure 16 bar
– Temperature +90°C
– Scale 0-100%
– Type plate with Fischer logo
– Marking with CE and UKCA
– Without manual
– O-rings in the closure bag enclosed with the device!
|
Code: DS3101YMYYAYD0014
Description: Differential pressure Switch
Measuring range/ switching range 0…0,6 bar/ 0,06…0,6 bar
Version (measuring system) brass/ NBR
With 1 adjustable mikroswitch; closer
Electrical connection
***
Switching function with rising pressure
max. pressure: 20 bar
Electrical connection: 1,5m silicone cable
Process connection:
Screw-in fitting GE6-PLR, brass
Type label: with Fischer-logo
Marking: with CE-and UKCA-sign
Operating instruction: Fischer
|
|
Code: DS3101YMYYAYD0014
Description: Different pressure switch
measuring range/ switching range 0…0,6 bar/ 0.06..0.6 bar
Version (measuring system) brass/ NBR
with 1 adjustable mikroswitch; closer electrical connection
***
Switching function with rising pressure
max pressure : 20 bar
Electrical connection: 1.5m silicone cable
Process connection:
Screw-in fitting GE6-PLR, brass
Type lable: with Fischer-logo
Marking: with CE-and UKCA-sign
Operating instruction: Fischer
|
Code: DE49B20040BH00MW
Description: EX digital differential pressure transmitter
Measuring range -25 ..+25 mbar
Version standard
Measuring unit standard (increasing curve)
Pressure connection threaded hose coupling for 6/4 mm hose
Electrical output signal 4-20mA (2-wire)
Power supply 12-30 VDC
Electrical connection M12 round shell multi pin connector
Mounting wall mounting plate
|
|
Code: NC562P1450PE2011
Description: Capacitance Level transmitter
design water/ waste water (1x shrink hose 1x bank)
plastic housing IP67
Insertion length 1450mm
output ingnal 4…29 Ma (3-wire)
power suppy 9..32V DC (for current output)
version 2011
|
Code: DE2802M290PL000P
Description: Differential pressure transmitter
Measuring range 0…1bar
Pressure chamber brass; diapraghm NBR
Pressure connection 8 mm cutting ring/ brass
Electrical connection M16x1,5 cabel connection
Output signal 4-20 mA, 3-wire
Power supply 24V AC/DC (20-30V)
Approval variants standard version
Protection IP65
|
|
Code: DS21010A21BK0W00U0700
Description: Differential Pressure Switch
Measuring range 0…0,6 bar
Application for hotwater and thermal oil
Pressure chamber Aluminium
Process connection 8 mm cutting ring/steel
With 2 adjustable microswitches
Electrical connection cable terminal box
Casing protection class IP55
Wall mounting
Version SIL 2
|
Code: DE90B30040P000000000
Description: digital differential pressure transmitter pro-line
Measuring range channel 1 – 60… + 60mbar
Measuring range channel 2 without
Process connection aluminium screw connection for 6mm hose
Output signal (preset) 4…20mA, 3-wire
Special function none
Special features: none
Approval not selected
lid color anthracite/ green
Membrane keypad Fischer
Configuration standard
|
|
Code: DE1601VA20B90H00
Description: Differential Pressure Transmitter
Measuring range 0 …0,6 bar
Measuring diaphragm/ gaskets Viton
Pressure chamber Aluminium
Pressure connection 6mm cutting ring/ steel
Output signal 4-20mA 2-wire
Power supply 24 VDC +-10%
Electrical connection plug acc. DIN EN 175301-803-A
|
Code: DE90B30040P000000001
Description: digital differential pressure transmitter pro-line
Measuring range channel 1 – 60… + 60mbar
Measuring range channel 2 without
Process connection aluminium screw connection for 6mm hose
Output signal (preset) 4…20mA, 3-wire
Special function none
Special features: none
Approval not selected
lid color anthracite/ green
Membrane keypad Fischer
Configuration linear characteristic curve
Parameternr DE90P1X0000001220
Measuring range C1 unit mbar
Measuring range C1 start -40
Measuring range C1 end +60
Limit C1 no
Number format C1 Standard
LCD Colour Red/ green
|